Mistura IoT — Setup Guide7 steps: the big picture first, then your account, network, gateway, live monitoring, recovered data and settings
Step 1 of 7
See how your data travels
Watch one reading leave the instrument, cross the RS-485 cable, pass through the gateway, travel to the cloud server over Wi-Fi, Ethernet or GSM, and appear on your live dashboard. This is what Steps 3 to 6 set up for you.
Live animation 6 stops, end to end
LIVE DEMOOrange = RS-485 · Coloured lane = active uplink · Green = dashboard
Uplink
What happens at each stop
1 · 2 Instruments → RS-485Each instrument measures and answers over Modbus RTU on a shared two-wire cable. Every unit on the cable needs its own device ID.
3 GatewayThe gateway sequentially polls each connected device and transmits both live data and log data (at a configurable interval). If log data transmission is unsuccessful, the data is retained locally on the gateway’s memory card for subsequent recovery and can later be retrieved using Log Manager (Step 6).
4 · 5 Internet → ServerOver Wi-Fi, Ethernet or cellular the gateway sends readings to the server. The server checks the gateway key and saves every value in the database.
6 DashboardDevice pages, GW Live, Customize and PDF reports all read the same database, so every screen shows the same numbers. An offline node turns red.
RS-485 wiring checklist
A+ to A+, B− to B−Run one twisted pair from the gateway through every device. If nothing answers, swap A and B once.
120 Ω at both endsFit a terminator on the first and the last device only, not on every unit.
Common groundJoin signal ground (shield or a third wire) so all devices share the same reference.
Same settingsSame baud rate and parity on every device, and a different ID on each unit. Use the same ID when you add it in Step 4.
Keep the cable away from power wiringRun the RS-485 pair apart from motor and mains cables, or cross them at right angles, to avoid noisy or missing readings.
Step 2 of 7
Create your Mistura-IoT account
Every workspace starts with a verified account. We email a one-time code, so only you can activate it. After that you can sign in and open the Main Dashboard.
About 2 minutes Needs a working email
What to do
1
Open the sign-up formOn this login page press Create New Account, just under the Sign In button.
2
Choose a usernameAt least 3 characters. This is what you type when you sign in.
3
Enter your email and a passwordUse a real email, because the code goes there. The password needs at least 4 characters; longer is safer.
4
Press Send Verification CodeA 6-digit code is emailed to you. It stays valid for 15 minutes.
5
Type the code and finishEnter it on the Verify Registration screen and press Complete Registration.
6
Sign inEnter your username and password, press Sign In and you land on the Main Dashboard.
Create Account
plant_admin
name@company.com
••••••••
Send Verification Code
48217
Complete Registration
The two screens you will see (example values)
You will know it worked when…the page confirms the code and you can sign in with your new username and password.
Good to know
Email does not arriveWait 2 minutes and check spam or promotions. You can register again with the same email; the earlier unverified entry is cleaned up automatically.
Forgot Password?Press the link above Sign In, enter your email, press Send Reset Code, then type the 6-digit code with a new password. The code is valid for 15 minutes.
Too many devicesAccounts allow about 2 active sessions on up to 4 devices by default. Sign out on an older browser, or ask your administrator to raise the limit.
Already usedA verified username or email cannot be registered again. Use Forgot Password if you lost access.
Step 3 of 7
Configure the gateway device network
Before the cloud can see your hardware, the gateway has to join your network. Do this once from the Settings button on this login page, using a USB cable or the gateway’s own Wi-Fi.
5–10 minutes Gateway powered on
What to do
1
Open the configuration pageOn the login screen press Settings (it opens /config).
2
Choose how to talk to the gatewaySerial USB is the easiest the first time. Wi-Fi AP works without a cable. Details are in the cards below.
3
Press Connect, then Enter SetupThe activity log at the bottom shows live messages from the gateway.
4
Pick the network typeWi-Fi (name + password), Ethernet, or Cellular (APN). Wi-Fi and Ethernet can use DHCP or a fixed address.
5
Press Apply & SaveWait for SUCCESS. The gateway reboots and joins your network.
6
Test the linkUse Ping before you leave to confirm the gateway is reachable.
Gateway Configuration
Serial USBWi-Fi AP
Select port ConnectEnter Setup
Wi-FiEthernetCellular
Plant-Office
••••••••
Apply & Save SUCCESS
Example — your page may be arranged a little differently
Pick your connection method
Serial USB (recommended first time)Plug the gateway into your computer with a data USB cable, press Select to choose the COM port, and connect at 115200 baud. Use a desktop Chrome or Edge browser.
Wi-Fi AP (no cable)Join the gateway’s own Wi-Fi (default name Gateway-Setup, password 12345678) from your phone or laptop, then press Connect on the page.
Change the access-point passwordThe default Wi-Fi AP password is public knowledge. Change it after the first setup so nobody else can reconfigure your gateway.
If it does not work
No COM ports listedInstall the CP210x or CH340 driver, try another USB cable (data-capable), and close any other serial monitor.
No SUCCESS messageRe-check the Wi-Fi name and password (they are case-sensitive), or the cable/APN for Ethernet and Cellular, then Apply & Save again.
Step 4 of 7
Add your gateway to your account
The gateway number and secret key are printed on the device label. Registering them ties its readings to your account. Then you add the instruments connected to it and send the setup to the gateway.
About 5 minutes Label: number + key
The three moves
Register hardware
Add devices
Sync config
What to do
1
Open Manage DevicesAfter signing in, use the Manage Devices quick button or the account menu.
2
Press Register HardwareEnter the gateway number (for example GW-001) and the case-sensitive gateway key. The status must show Available.
3
Add gateway informationOptional note such as “Boiler house, Plant 2”. It appears on the gateway card.
4
Press RegisterA gateway card appears with 0 / 8 devices (the limit can differ).
5
Add each deviceChoose the gateway, the device type, the device ID (it must match the address set on the physical unit), a name and the log interval.
6
Sync ConfigPress Sync Config on the card, then Send All to GateWay. Wait for the green Configuration Saved on Gateway!
Manage Devices
GW-001
••••••••
Available
Boiler house, Plant 2
Register
Gateway-1000 3 / 8 devices
Sync Config
Registration form, then the new gateway card
Supported devices
TemperatureMS9700 8-channel scanner, MS9600, MHT9611 temperature + humidity, PTC9611 / PTC9611R process temperature.
Power & motorsAVH9611 energy meter and MPD9611 motor protection.
You will know it worked when…the gateway card shows your devices, the sync turns green, and live values start arriving within one sample interval.
Want the full walkthrough?The Manage Devices page has its own Setup Guide with editing, removing devices and unregistering a gateway.
Stuck on red / no ACK?Check that the gateway has power, is online (Step 3) and can reach the cloud, then press Send All again. Keep the gateway key private.
Step 5 of 7
Watch your plant live
There are four ways to see your data, from one device up to an unattended wall screen. Pick the one that fits and tap its card below. All of them start from the gateway cards on the Main Dashboard.
Updates every few seconds Six colour themes
1
Show the devicesOn a gateway card press Show Devices. Each device is listed with its type.
2
Open onePress the device row. The small arrow button opens it in a new browser tab instead.
3
Read the pageEvery device type has its own page: live gauges, trend charts, channel values, an ONLINE / OFFLINE status and alarm colours.
4
Make reportsPick a target date or a custom date range, then export a PDF table or PDF graph.
5
Tune the pageUse Settings, Theme and the panel buttons to change chart height, charts per row and which panels show. Press M if the settings button is hard to see.
Temperature scanner · Boiler 1
ONLINEGateway-1000 · Device 1
84°
CH1
112°
CH2
158°
CH3
PDF table PDF graph
Amber and red mean a channel passed its warning or critical limit
Channel names & alarm limitsRename channels (for example “Motor bearing”) and set warning and critical limits from the device page settings. Limits drive the colours you see here and on GW Live.
1
Open GW LiveAfter pressing Show Devices, press GW Live at the bottom of the card.
2
See every device togetherEach device appears as a live card that matches its type: energy tiles, 8-channel scanner, climate, motor protection and more. A LIVE pill shows the data is flowing.
3
Choose a view modeScroll for one long page, Paging for pages of devices, or Auto to flip pages by itself. Set devices per page and the auto page-shift time.
4
Style itOpen Settings for theme, horizontal or vertical gauge layout, scroll speed, full screen and hiding the top header.
5
Adjust one deviceEach card has its own panel settings: collapse, drag to move, a display name for this screen, and see-through.
Gateway Live · Gateway-1000
LIVEPage 1 / 2 · Paging mode
Boiler 1 · avg96.4°C
Main incomer · kW42.8
Store room · RH71 %
Pump motor · A18.9
ScrollPagingAuto
Your own screen may show gauges or tiles, depending on device type
1
Open the Dashboard buttonOn the gateway card press Dashboard. A small chooser asks how to open it.
2
View mode or CustomizeView mode is a read-only live dashboard for everyone. Customize lets you edit the layout and widgets.
3
Choose how to startFirst time you can start with an empty canvas, let it generate KPIs, trends and tables for every device, or load a layout from a JSON file you exported.
4
Add and arrange widgetsPress Add widget, search, then drag onto the canvas. Move, resize, duplicate or remove each one, and open its settings for icon, unit, colours and text style.
5
Finish the lookSet grid size, canvas width, theme, fonts, and the backgrounds of the top panel and page. Switch Edit mode off to see the final result.
Customize Dashboard
Edit modeAdd widgetThemeText style
Plant overview
Boiler 1 temperature 96.4°C
Main incomer 42.8 kW
Pump 18.9 A
Store 71 %
+ drop a widget
The selected widget (orange outline) can be moved, resized or edited
Share a layoutYou can export a layout as a JSON file and load it on another gateway or another screen.
1
Press Auto ModeUse the Auto Mode quick button, or the same item in the account menu. The Launch Kiosk Mode window opens.
2
Pick the gatewaysTick the ones to include, or Select All. A gateway with no devices is greyed out.
3
Choose mode and timeAuto moves on by itself; Manual uses Next and Previous buttons. For Auto pick 1, 5 or 10 minutes per device. The summary shows the total loop time.
4
Press LaunchKiosk opens in a new tab. Click once to go full screen; after that it keeps cycling through every device.
5
Control it←→ previous / next · M auto / manual · S auto scroll · ↑↓ scroll. Use Exit kiosk to leave.
Launch Kiosk Mode
Gateway-10003 devices
Gateway-10012 devices
AutoTimedManualButtons
1 minFast5 minBalanced10 minRelaxed
Example: 5 devices × 5 min = 25 min per full loop
Launch
Example values
You’re live when…status pills are green and timestamps keep moving. An offline node shows a red status instead of a value.
Device Setup (admin accounts)The Device Setup button on the gateway card writes setup values to your devices.
Step 6 of 7
Log Manager — recover offline data
When the network drops, the gateway keeps recording. Log Manager pulls that stored file from the gateway and inserts the missing rows into your database, with no duplicates, so charts and reports have no gaps.
A few minutes Password confirmed
What to do
1
Open Log ManagerPress Log Manager on the dashboard (History & exports). Make sure the gateway is back online first.
2
Choose gateway and sensorPick the gateway and the device (sensor) that missed data.
3
Press Get Offline DataThe status shows WAITING FOR FILE while the gateway uploads what it stored.
4
Review the tableTick the rows you want, or press Select All.
5
Press Insert SelectedConfirm with your password. The rows are written to the database.
6
Duplicates are skippedRows already stored are marked Already in DB and ignored, so nothing is counted twice.
Log Manager
Gateway-1000
Boiler 1
Get Offline Data
WAITING FOR FILE…
☑TimeValueStatus
☑10:02:0084.1New
☑10:03:0084.6New
☐10:04:0085.0Already in DB
Select All Insert Selected
Illustration — column names on your page may differ
Safe by designInserting needs your password and never double-counts history, so you can repeat the recovery without worry.
If it does not work
Stays on WAITING FOR FILEThe gateway may be offline or busy. Check its power and network (Step 3), wait a minute, then press Get Offline Data again.
Every row says Already in DBNothing was missing for that period — the data had already reached the cloud.
Step 7 of 7
Make it yours — settings & looks
On the Main Dashboard open Settings from the account menu, press the round slider button at the bottom-right, or press M. Your choices are saved on that device, so a phone, a laptop and a wall TV can each look different.
Saved per device Export / import
The six tabs
ScreenPick your screen type (or Auto), then whole-page size, text size and button size.
Look & feelTheme, accent colour, card style (solid, glass, flat, outline), corner roundness, font, high contrast and animations.
LayoutCards per row, card size, spacing, page width, edge space and the top bar (fixed, scrolls away or hidden).
BackgroundPatterns, gradients, a solid colour or your own picture, plus soft glow blobs.
Show / HideWelcome banner, quick buttons, search box, footer line, and opening device lists automatically.
Large screenLarge-screen mode, auto-scroll, mouse pointer, keep screen awake, full screen on first touch, dimmer and auto refresh.
Settings
ScreenLook & feelLayoutBackground
Deep Ocean
Carbon
Sunset
Emerald
Paper Light
Pure Light
Open device lists automatically
High contrast
Example — the real panel has more options
Your accountOpen the account menu for Change Password and Sign out. Live pages (GW Live, device pages and Customize) also have their own Settings and Theme buttons.
All done!Account created, gateway online and registered, live views ready and data recovered when needed. Reopen this guide anytime with Setup Guide on the login page.